Operational Check of LP Shut Off Valves including Operation by Individual MotorsOperational Check of LP Shut Off Valves including Operation by Individual Motors
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
THE FLIGHT CONTROLSTHE FLIGHT CONTROLSTHE FLIGHT CONTROL SURFACESTHE FLIGHT CONTROL SURFACESTHE LANDING GEAR AND THE RELATED DOORSTHE LANDING GEAR AND THE RELATED DOORSCOMPONENTS THAT MOVE.COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE
EQUIPMENT.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE
EQUIPMENT.
210522622
12QM
13QMReason for the JobReason for the JobRefer to the MPD TASK: 282400-02Refer to the MPD TASK: 282400-02OPERATIONAL CHECK OF LP SHUT OFF VALVES INCLUDING OPERATION BY INDIVIDUAL MOTORSOPERATIONAL CHECK OF LP SHUT OFF VALVES INCLUDING OPERATION BY INDIVIDUAL MOTORSJob Set-up InformationJob Set-up InformationFixtures, Tools, Test and Support EquipmentFixtures, Tools, Test and Support Equipment
REFERENCEREFERENCEQTYQTYDESIGNATIONDESIGNATIONNo specificNo specificARARACCESS PLATFORM 4M (13 FT)-ADJUSTABLEACCESS PLATFORM 4M (13 FT)-ADJUSTABLENo specificNo specificARARSAFETY BARRIER(S)SAFETY BARRIER(S)No specificNo specificARARSAFETY CLIP - CIRCUIT BREAKERSAFETY CLIP - CIRCUIT BREAKERNo specificNo specificARARWARNING NOTICE(S)WARNING NOTICE(S)Work Zones and Access PanelsWork Zones and Access Panels
ZONE/ACCESSZONE/ACCESSZONE DESCRIPTIONZONE DESCRIPTION210210CKPT,FWD COMPT BHD TO FLT COMPT BULKHEADCKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD522522OUTBOARD FIXED L.E STRUCTUREOUTBOARD FIXED L.E STRUCTURE622622OUTBOARD FIXED L.E STRUCTUREOUTBOARD FIXED L.E STRUCTUREFOR10QG(ACTUATOR-LP FUEL VALVE, ENG 2)FOR10QG(ACTUATOR-LP FUEL VALVE, ENG 2)622AT622AT
622AB622AB
622XB622XBFOR9QG(ACTUATOR-LP FUEL VALVE, ENG 1)FOR9QG(ACTUATOR-LP FUEL VALVE, ENG 1)522AT522AT
522XB522XB
522AB522ABJob Set-upJob Set-up
Safety PrecautionsSafety Precautions
OBEY THE FUEL SAFETY PROCEDURES. THIS CAN PREVENT INJURY AND DAMAGE.
OBEY THE FUEL SAFETY PROCEDURES. THIS CAN PREVENT INJURY AND DAMAGE.
You must obey the fuel safety procedures when you do work on the fuel
system
28-00-00-910-00128-00-00-910-001-A.
You must obey the fuel safety procedures when you do work on the fuel
system
28-00-00-910-00128-00-00-910-001-A.
As necessary, use the applicable SAFETY BARRIER(S), specified by the
operator's instructions and your local regulations.
As necessary, use the applicable SAFETY BARRIER(S), specified by the
operator's instructions and your local regulations.
Aircraft Maintenance ConfigurationAircraft Maintenance Configuration
On panel 20VU, make sure that ENG 1 and ENG 2 FIRE pushbutton switches are in
closed and guarded position.
On panel 20VU, make sure that ENG 1 and ENG 2 FIRE pushbutton switches are in
closed and guarded position.
On panel 115VU, make sure that ENG/MASTER 1 and ENG/MASTER 2 switches are in
OFF position.
On panel 115VU, make sure that ENG/MASTER 1 and ENG/MASTER 2 switches are in
OFF position.
Put theWARNING NOTICE(S)
in position on panel 20VU to tell persons not to operate ENG 1 and ENG 2
FIRE pushbutton switches.
Put theWARNING NOTICE(S)
in position on panel 20VU to tell persons not to operate ENG 1 and ENG 2
FIRE pushbutton switches.
Put theWARNING NOTICE(S)
in position on panel 115VU to tell persons not to operate ENG/MASTER 1 and
ENG/MASTER 2 switches.
Put theWARNING NOTICE(S)
in position on panel 115VU to tell persons not to operate ENG/MASTER 1 and
ENG/MASTER 2 switches.
Fully extend the slats27-80-00-866-00427-80-00-866-004-A.Fully extend the slats27-80-00-866-00427-80-00-866-004-A.Make sure that theLOCKING TOOL-FLAP SLAT LEVER,INT. POSITION98D27803000000is installed on the slat/flap control lever.Make sure that theLOCKING TOOL-FLAP SLAT LEVER,INT. POSITION98D27803000000is installed on the slat/flap control lever.Put theWARNING NOTICE(S)in position to tell persons not to operate the slats.Put theWARNING NOTICE(S)in position to tell persons not to operate the slats.Make sure that the APU does not operate and there is no bleed air.Make sure that the APU does not operate and there is no bleed air.Energize the aircraft electrical circuitsEnergize the aircraft electrical circuits24-41-00-861-00224-41-00-861-002-A24-41-00-861-002-A-0124-41-00-861-002-A-02.24-41-00-861-00224-41-00-861-002-A24-41-00-861-002-A-0124-41-00-861-002-A-02.Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)31-60-00-860-00131-60-00-860-001-A.31-60-00-860-00131-60-00-860-001-A.
On ECAM Control Panel (CP) 11VU, push the FUEL pushbutton switches to get the
FUEL page on the ECAM lower DU.
On ECAM Control Panel (CP) 11VU, push the FUEL pushbutton switches to get the
FUEL page on the ECAM lower DU.
On the FUEL page, make sure that the cross-feed valve indication shows green
cross-line (valve closed).
On the FUEL page, make sure that the cross-feed valve indication shows green
cross-line (valve closed).
Make sure that this (these) circuit breaker(s) is (are) closed:Make sure that this (these) circuit breaker(s) is (are) closed:
2QGFUEL/LP VALVE/MOT1/ENG249VUA09
1QGFUEL/LP VALVE/MOT1/ENG149VUA08
4QGFUEL/LP VALVE/MOT2/ENG2121VUM26
3QGFUEL/LP VALVE/MOT2/ENG1121VUM25
Open, safety and tag the circuit breaker(s) that follow(s). Use the SAFETY CLIP -
CIRCUIT BREAKER as necessary.
Open, safety and tag the circuit breaker(s) that follow(s). Use the SAFETY CLIP -
CIRCUIT BREAKER as necessary.
5CVFLIGHT CONTROLS/SLT/CTL AND MONG/SYS149VUB06
5CVFLIGHT CONTROLS/SLT/CTL AND MONG/SYS149VUB01
7CVFLIGHT CONTROLS/SLT/CTL/SYS2121VUR21
Get AccessGet AccessPut theACCESS PLATFORM 4M (13 FT)-ADJUSTABLEin position below the applicable zone 522(622).Put theACCESS PLATFORM 4M (13 FT)-ADJUSTABLEin position below the applicable zone 522(622).Remove the applicable access panel:Remove the applicable access panel:FOR9QG(ACTUATOR-LP FUEL VALVE, ENG 1)FOR9QG(ACTUATOR-LP FUEL VALVE, ENG 1)Remove522AT57-41-37-000-00357-41-37-000-003-Aor522XB57-41-37-000-00457-41-37-000-004-A.Remove522AT57-41-37-000-00357-41-37-000-003-Aor522XB57-41-37-000-00457-41-37-000-004-A.FOR10QG(ACTUATOR-LP FUEL VALVE, ENG 2)FOR10QG(ACTUATOR-LP FUEL VALVE, ENG 2)Remove622AT57-41-37-000-00357-41-37-000-003-Aor622XB57-41-37-000-00457-41-37-000-004-A.Remove622AT57-41-37-000-00357-41-37-000-003-Aor622XB57-41-37-000-00457-41-37-000-004-A.
Get AccessGet AccessPut theACCESS PLATFORM 4M (13 FT)-ADJUSTABLEin position below applicable zone 522 (622).Put theACCESS PLATFORM 4M (13 FT)-ADJUSTABLEin position below applicable zone 522 (622).Remove the applicable access panel:Remove the applicable access panel:FOR9QG(ACTUATOR-LP FUEL VALVE, ENG 1)FOR9QG(ACTUATOR-LP FUEL VALVE, ENG 1)Remove522AT57-41-37-000-00357-41-37-000-003-Aor522AB57-41-37-000-00457-41-37-000-004-A.Remove522AT57-41-37-000-00357-41-37-000-003-Aor522AB57-41-37-000-00457-41-37-000-004-A.FOR10QG(ACTUATOR-LP FUEL VALVE, ENG 2)FOR10QG(ACTUATOR-LP FUEL VALVE, ENG 2)Remove622AT57-41-37-000-00357-41-37-000-003-Aor622AB57-41-37-000-00457-41-37-000-004-A.Remove622AT57-41-37-000-00357-41-37-000-003-Aor622AB57-41-37-000-00457-41-37-000-004-A.
ProcedureProcedureComponent Location - CockpitComponent Location - Cockpit
Operational Check of LP Shut Off Valves including Operation by Individual Motors
Operational Check of LP Shut Off Valves including Operation by Individual Motors
In the test that follows, on each operation of the LP valve:In the test that follows, on each operation of the LP valve:
Make sure that the see/feel indicator operates smoothly from the valve
open (valve closed) position to the valve closed (valve open)
position.
Make sure that the see/feel indicator operates smoothly from the valve
open (valve closed) position to the valve closed (valve open)
position.
Make sure that the see/feel indicator marks are accurately aligned
with the valve open position.
Make sure that the see/feel indicator marks are accurately aligned
with the valve open position.
Make sure that the see/feel indicator marks are at 90 deg (90 deg) to
each other with the valve closed position.
Make sure that the see/feel indicator marks are at 90 deg (90 deg) to
each other with the valve closed position.
For valve 12QM, do this test:For valve 12QM, do this test:
ACTIONACTIONRESULTRESULT1.On panel 121VU:1.On panel 121VU:Open, safety and tag circuit breaker 3QG.Open, safety and tag circuit breaker 3QG.
ENG 1 LP valve MOTOR 2 SUPPLY and CONTROL are
isolated.
ENG 1 LP valve MOTOR 2 SUPPLY and CONTROL are
isolated.
On the ECAM lower DU:On the ECAM lower DU:
The LEFT LP valve indication shows that the valve
is closed (amber cross-line).
The LEFT LP valve indication shows that the valve
is closed (amber cross-line).
2.On LP-valve actuator 9QG:2.On LP-valve actuator 9QG:
Examine the position of the mechanical see/feel
indicator.
Examine the position of the mechanical see/feel
indicator.
The indicator shows that the valve is closed.
The indicator shows that the valve is closed.
3.On panel 115VU:3.On panel 115VU:
Set ENG/MASTER 1 switch to the ON position.
Set ENG/MASTER 1 switch to the ON position.
On the ECAM lower DU:On the ECAM lower DU:
The LEFT LP valve indication shows that the valve
is open (green in-line).
The LEFT LP valve indication shows that the valve
is open (green in-line).
4.On LP-valve actuator 9QG:4.On LP-valve actuator 9QG:
Listen to the actuator motor and measure the time
that it operates for as the LP valve opens.
Listen to the actuator motor and measure the time
that it operates for as the LP valve opens.
Examine the position of the mechanical see/feel
indicator.
Examine the position of the mechanical see/feel
indicator.
The actuator motor must not operate for more than
5 seconds.
The actuator motor must not operate for more than
5 seconds.
The indicator shows that the valve is open.
The indicator shows that the valve is open.
5.On panel 115VU:5.On panel 115VU:
Set ENG/MASTER 1 switch to the OFF position.
Set ENG/MASTER 1 switch to the OFF position.
On the ECAM lower DU:On the ECAM lower DU:
The LEFT LP valve indication shows that the valve
is closed (amber cross-line).
The LEFT LP valve indication shows that the valve
is closed (amber cross-line).
6.On LP-valve actuator 9QG:6.On LP-valve actuator 9QG:
Listen to the actuator motor and measure the time
that it operates for as the LP valve closes.
Listen to the actuator motor and measure the time
that it operates for as the LP valve closes.
Examine the position of the mechanical see/feel
indicator.
Examine the position of the mechanical see/feel
indicator.
The actuator motor must not operate for more than
5 seconds.
The actuator motor must not operate for more than
5 seconds.
The indicator shows that the valve is closed.
The indicator shows that the valve is closed.
7.On panel 121VU:7.On panel 121VU:
Remove the safety clip and the tag and close
circuit breaker 3QG.
Remove the safety clip and the tag and close
circuit breaker 3QG.
ENG 1 LP valve MOTOR 2 SUPPLY and CONTROL are
energized.
ENG 1 LP valve MOTOR 2 SUPPLY and CONTROL are
energized.
8.On panel 49VU:8.On panel 49VU:Open, safety and tag circuit breaker 1QG.Open, safety and tag circuit breaker 1QG.
ENG 1 LP valve MOTOR 1 SUPPLY and CONTROL are
isolated.
ENG 1 LP valve MOTOR 1 SUPPLY and CONTROL are
isolated.
On the ECAM lower DU:On the ECAM lower DU:
The LEFT LP valve indication shows that the valve
is closed (amber cross-line).
The LEFT LP valve indication shows that the valve
is closed (amber cross-line).
9.On LP-valve actuator 9QG:9.On LP-valve actuator 9QG:
Examine the position of the mechanical see/feel
indicator.
Examine the position of the mechanical see/feel
indicator.
The indicator shows that the valve is closed.
The indicator shows that the valve is closed.
10.On panel 115VU:10.On panel 115VU:
Set ENG/MASTER 1 switch to the ON position.
Set ENG/MASTER 1 switch to the ON position.
On the ECAM lower DU:On the ECAM lower DU:
The LEFT LP valve indication shows that the valve
is open (green in-line).
The LEFT LP valve indication shows that the valve
is open (green in-line).
11.On LP-valve actuator 9QG:11.On LP-valve actuator 9QG:
Listen to the actuator motor and measure the time
that it operates for as the LP valve opens.
Listen to the actuator motor and measure the time
that it operates for as the LP valve opens.
Examine the position of the mechanical see/feel
indicator.
Examine the position of the mechanical see/feel
indicator.
The actuator motor must not operate for more than
5 seconds.
The actuator motor must not operate for more than
5 seconds.
The indicator shows that the valve is open.
The indicator shows that the valve is open.
12.On panel 115VU:12.On panel 115VU:
Set ENG/MASTER 1 switch to the OFF position.
Set ENG/MASTER 1 switch to the OFF position.
On the ECAM lower DU:On the ECAM lower DU:
The LEFT LP valve indication shows that the valve
is closed (amber cross-line).
The LEFT LP valve indication shows that the valve
is closed (amber cross-line).
13.On LP-valve actuator 9QG:13.On LP-valve actuator 9QG:
Listen to the actuator motor and measure the time
that it operates for as the LP valve closes.
Listen to the actuator motor and measure the time
that it operates for as the LP valve closes.
Examine the position of the mechanical see/feel
indicator.
Examine the position of the mechanical see/feel
indicator.
The actuator motor must not operate for more than
5 seconds.
The actuator motor must not operate for more than
5 seconds.
The indicator shows that the valve is closed.
The indicator shows that the valve is closed.
14.On panel 49VU:14.On panel 49VU:
Remove the safety clip and the tag and close
circuit breaker 1QG.
Remove the safety clip and the tag and close
circuit breaker 1QG.
ENG 1 LP valve MOTOR 1 SUPPLY and CONTROL are
energized.
ENG 1 LP valve MOTOR 1 SUPPLY and CONTROL are
energized.
For valve 13QM, do this test:For valve 13QM, do this test:
ACTIONACTIONRESULTRESULT1.On panel 121VU:1.On panel 121VU:Open, safety and tag circuit breaker 4QG.Open, safety and tag circuit breaker 4QG.
ENG 2 LP valve MOTOR 2 SUPPLY and CONTROL are
isolated.
ENG 2 LP valve MOTOR 2 SUPPLY and CONTROL are
isolated.
On the ECAM lower DU:On the ECAM lower DU:
The RIGHT LP valve indication shows that the valve
is closed (amber cross-line).
The RIGHT LP valve indication shows that the valve
is closed (amber cross-line).
2.On LP-valve actuator 10QG:2.On LP-valve actuator 10QG:
Examine the position of the mechanical see/feel
indicator.
Examine the position of the mechanical see/feel
indicator.
The indicator shows that the valve is closed.
The indicator shows that the valve is closed.
3.On panel 115VU:3.On panel 115VU:
Set ENG/MASTER 2 switch to the ON position.
Set ENG/MASTER 2 switch to the ON position.
On the ECAM lower DU:On the ECAM lower DU:
The RIGHT LP valve indication shows that the valve
is open (green in-line).
The RIGHT LP valve indication shows that the valve
is open (green in-line).
4.On LP-valve actuator 10QG:4.On LP-valve actuator 10QG:
Listen to the actuator motor and measure the time
that it operates for as the LP valve opens.
Listen to the actuator motor and measure the time
that it operates for as the LP valve opens.
Examine the position of the mechanical see/feel
indicator.
Examine the position of the mechanical see/feel
indicator.
The actuator motor must not operate for more than
5 seconds.
The actuator motor must not operate for more than
5 seconds.
The indicator shows that the valve is open.
The indicator shows that the valve is open.
5.On panel 115VU:5.On panel 115VU:
Set ENG/MASTER 2 switch to the OFF position.
Set ENG/MASTER 2 switch to the OFF position.
On the ECAM lower DU:On the ECAM lower DU:
The RIGHT LP valve indication shows that the valve
is closed (amber cross-line).
The RIGHT LP valve indication shows that the valve
is closed (amber cross-line).
6.On LP-valve actuator 10QG:6.On LP-valve actuator 10QG:
Listen to the actuator motor and measure the time
that it operates for as the LP valve closes.
Listen to the actuator motor and measure the time
that it operates for as the LP valve closes.
Examine the position of the mechanical see/feel
indicator.
Examine the position of the mechanical see/feel
indicator.
The actuator motor must not operate for more than
5 seconds.
The actuator motor must not operate for more than
5 seconds.
The indicator shows that the valve is closed.
The indicator shows that the valve is closed.
7.On panel 121VU:7.On panel 121VU:
Remove the safety clip and the tag and close
circuit breaker 4QG.
Remove the safety clip and the tag and close
circuit breaker 4QG.
ENG 2 LP valve MOTOR 2 SUPPLY and CONTROL are
energized.
ENG 2 LP valve MOTOR 2 SUPPLY and CONTROL are
energized.
8.On panel 49VU:8.On panel 49VU:Open, safety and tag circuit breaker 2QG.Open, safety and tag circuit breaker 2QG.
ENG 2 LP valve MOTOR 1 SUPPLY and CONTROL are
isolated.
ENG 2 LP valve MOTOR 1 SUPPLY and CONTROL are
isolated.
On the ECAM lower DU:On the ECAM lower DU:
The RIGHT LP valve indication shows that the valve
is closed (amber cross-line).
The RIGHT LP valve indication shows that the valve
is closed (amber cross-line).
9.On LP-valve actuator 10QG:9.On LP-valve actuator 10QG:
Examine the position of the mechanical see/feel
indicator.
Examine the position of the mechanical see/feel
indicator.
The indicator shows that the valve is closed.
The indicator shows that the valve is closed.
10.On panel 115VU:10.On panel 115VU:
Set ENG/MASTER 2 switch to the ON position.
Set ENG/MASTER 2 switch to the ON position.
On the ECAM lower DU:On the ECAM lower DU:
The RIGHT LP valve indication shows that the valve
is open (green in-line).
The RIGHT LP valve indication shows that the valve
is open (green in-line).
11.On LP-valve actuator 10QG:11.On LP-valve actuator 10QG:
Listen to the actuator motor and measure the time
that it operates for as the LP valve opens.
Listen to the actuator motor and measure the time
that it operates for as the LP valve opens.
Examine the position of the mechanical see/feel
indicator.
Examine the position of the mechanical see/feel
indicator.
The actuator motor must not operate for more than
5 seconds.
The actuator motor must not operate for more than
5 seconds.
The indicator shows that the valve is open.
The indicator shows that the valve is open.
12.On panel 115VU:12.On panel 115VU:
Set ENG/MASTER 2 switch to the OFF position.
Set ENG/MASTER 2 switch to the OFF position.
On the ECAM lower DU:On the ECAM lower DU:
The RIGHT LP valve indication shows that the valve
is closed (amber cross-line).
The RIGHT LP valve indication shows that the valve
is closed (amber cross-line).
13.On LP-valve actuator 10QG:13.On LP-valve actuator 10QG:
Listen to the actuator motor and measure the time
that it operates for as the LP valve closes.
Listen to the actuator motor and measure the time
that it operates for as the LP valve closes.
Examine the position of the mechanical see/feel
indicator.
Examine the position of the mechanical see/feel
indicator.
The actuator motor must not operate for more than
5 seconds.
The actuator motor must not operate for more than
5 seconds.
The indicator shows that the valve is closed.
The indicator shows that the valve is closed.
14.On panel 49VU:14.On panel 49VU:
Remove the safety clip and the tag and close
circuit breaker 2QG.
Remove the safety clip and the tag and close
circuit breaker 2QG.
ENG 2 LP valve MOTOR 1 SUPPLY and CONTROL are
energized.
ENG 2 LP valve MOTOR 1 SUPPLY and CONTROL are
energized.
Close-upClose-up
Close AccessClose AccessInstall the applicable access panel:Install the applicable access panel:FOR9QG(ACTUATOR-LP FUEL VALVE, ENG 1)FOR9QG(ACTUATOR-LP FUEL VALVE, ENG 1)Install522AT57-41-37-400-00357-41-37-400-003-Aor522XB57-41-37-400-00257-41-37-400-002-A.Install522AT57-41-37-400-00357-41-37-400-003-Aor522XB57-41-37-400-00257-41-37-400-002-A.FOR10QG(ACTUATOR-LP FUEL VALVE, ENG 2)FOR10QG(ACTUATOR-LP FUEL VALVE, ENG 2)Install622AT57-41-37-400-00357-41-37-400-003-Aor622XB57-41-37-400-00257-41-37-400-002-A.Install622AT57-41-37-400-00357-41-37-400-003-Aor622XB57-41-37-400-00257-41-37-400-002-A.
Close AccessClose Access
Make sure that the work area is clean and clear of tools and other items.
Make sure that the work area is clean and clear of tools and other items.
Install the applicable access panel:Install the applicable access panel:FOR9QG(ACTUATOR-LP FUEL VALVE, ENG 1)FOR9QG(ACTUATOR-LP FUEL VALVE, ENG 1)Install522AT57-41-37-400-00357-41-37-400-003-Aor522AB57-41-37-400-00257-41-37-400-002-A.Install522AT57-41-37-400-00357-41-37-400-003-Aor522AB57-41-37-400-00257-41-37-400-002-A.FOR10QG(ACTUATOR-LP FUEL VALVE, ENG 2)FOR10QG(ACTUATOR-LP FUEL VALVE, ENG 2)Install622AT57-41-37-400-00357-41-37-400-003-Aor622AB57-41-37-400-00257-41-37-400-002-A.Install622AT57-41-37-400-00357-41-37-400-003-Aor622AB57-41-37-400-00257-41-37-400-002-A.
Remove the SAFETY CLIP - CIRCUIT BREAKER and the tag(s) and close this (these) circuit
breaker(s):
Remove the SAFETY CLIP - CIRCUIT BREAKER and the tag(s) and close this (these) circuit
breaker(s):
5CVFLIGHT CONTROLS/SLT/CTL AND MONG/SYS149VUB06
5CVFLIGHT CONTROLS/SLT/CTL AND MONG/SYS149VUB01
7CVFLIGHT CONTROLS/SLT/CTL/SYS2121VUR21
Aircraft Maintenance ConfigurationAircraft Maintenance ConfigurationFully retract the slats27-80-00-866-00527-80-00-866-005-A.Fully retract the slats27-80-00-866-00527-80-00-866-005-A.On the ECAM lower DU, make sure that the LP valves are closed.On the ECAM lower DU, make sure that the LP valves are closed.Do the EIS stop procedure31-60-00-860-00231-60-00-860-002-A.Do the EIS stop procedure31-60-00-860-00231-60-00-860-002-A.De-energize the aircraft electrical circuits24-41-00-862-00224-41-00-862-002-A24-41-00-862-002-A-0124-41-00-862-002-A-02.De-energize the aircraft electrical circuits24-41-00-862-00224-41-00-862-002-A24-41-00-862-002-A-0124-41-00-862-002-A-02.
Removal of EquipmentRemoval of EquipmentRemove the SAFETY BARRIERS.Remove the SAFETY BARRIERS.Remove the access platform(s).Remove the access platform(s).Remove the WARNING NOTICE(S).Remove the WARNING NOTICE(S).
Remove the ground support and maintenance equipment, the special and standard
tools and all other items.
Remove the ground support and maintenance equipment, the special and standard
tools and all other items.